Solar ground screws are commonly used as foundation components for ground-mounted photovoltaic systems, solar carports and other outdoor structures. Their performance depends on more than steel dimensions and manufacturing quality. Soil conditions, installation depth, installation quality and the loads transferred from the mounting structure all influence foundation behavior.
For EPC contractors and solar mounting system designers, evaluating a ground screw requires more than checking a product specification sheet. Compression, pull-out and lateral resistance are different mechanical properties and should be assessed separately.
This guide explains how solar ground screw load testing is evaluated, presents PV Mounts’ SGS mechanical test results, discusses pull strength reference data and explains how soil conditions affect ground screw foundation performance.
Quick Answer: How Is Solar Ground Screw Load Capacity Evaluated?
Solar ground screw foundation performance is generally evaluated under three loading directions:
| Load direction | What it evaluates | Typical engineering concern |
|---|---|---|
| Axial compression | Resistance to downward loading along the screw axis | Vertical loads transferred from the PV structure |
| Axial tension / pull-out | Resistance to upward loading along the screw axis | Wind uplift and overturning effects |
| Lateral loading | Resistance to horizontal loading and associated displacement | Wind-induced horizontal forces and structural stability |
These three behaviors are not interchangeable.
PV Mounts has SGS mechanical test information for a ground screw specimen. The specimen was supported at two points and loaded vertically at the midpoint. The reported maximum compressive force was 1,680 kgf (approximately 16.47 kN), with a corresponding displacement of 18.382 mm.
Because the loading arrangement was a transverse, mid-span loading configuration, the result should be interpreted as a three-point-bending-type mechanical test of the specimen. It does not establish the axial compression capacity, pull-out resistance or lateral resistance of a ground screw installed in soil.
For project-specific foundation design, engineers should consider the ground screw geometry, embedment depth, soil investigation data, installation conditions and appropriate field load tests.
1. Why Solar Ground Screw Load Testing Matters
Ground screws transfer structural loads into the surrounding soil through their shaft, helical plates or other bearing components. Their resistance is influenced by the interaction between the steel foundation element and the ground.
A ground screw that performs well in one soil condition may behave differently in another. Dense sand, loose sand, stiff cohesive soil and soft clay can produce different load-displacement responses.
For EPC projects, mechanical testing and geotechnical evaluation help engineers assess whether the selected foundation configuration is suitable for the actual project conditions.
The main engineering objectives are to:
- Evaluate the load-displacement response of a ground screw.
- Assess axial compression and tensile resistance separately.
- Understand the influence of soil conditions and embedment depth.
- Identify potential excessive displacement or structural deformation.
- Provide project-specific information for foundation design and installation acceptance.
Important: A manufacturer’s product dimensions or material specifications cannot independently establish the allowable foundation capacity. The final design must consider the site investigation, installation method, structural loads and applicable engineering criteria.
2. Understanding Different Ground Screw Load Tests
2.1 Axial Compression Test
An axial compression test applies a downward load along the longitudinal axis of an installed ground screw or foundation element.
The test measures the relationship between the applied axial load and the resulting vertical displacement.
Engineers may use the results to evaluate:
- Axial load resistance under downward loading.
- Vertical displacement at specified load levels.
- Load-displacement behavior during loading and unloading.
- Whether the foundation response satisfies project-specific serviceability and strength requirements.
For deep foundation elements, ASTM D1143/D1143M provides a reference method for static axial compressive load testing.
An important distinction must be made between an axial compression test of an installed foundation and a mechanical test of a steel specimen. A specimen supported at two points and loaded transversely at its midpoint is mechanically different from an installed foundation axial compression test.
2.2 Axial Pull-Out Test
A pull-out test applies an upward force along the ground screw axis.
This test is particularly relevant to solar mounting structures because wind uplift can generate tensile forces at foundation connections.
The measured response may include:
- Applied tensile load.
- Axial displacement.
- Load at defined displacement levels.
- Maximum test load.
- Residual displacement after unloading, where recorded.
The pull-out resistance of a ground screw depends on several factors:
- Soil type and strength.
- Ground screw diameter and helical plate geometry.
- Embedment depth.
- Installation method and disturbance of the surrounding soil.
- Groundwater conditions.
- Load application and test procedure.
ASTM D3689/D3689M provides a reference method for static axial tensile load testing of deep foundation elements.
A pull-out value should not automatically be treated as an allowable design resistance. Engineers must interpret test results using the applicable design method and project-specific safety requirements.
2.3 Lateral Load Test
A lateral load test applies a horizontal force to a ground screw or foundation element.
The test evaluates the relationship between horizontal load and lateral displacement.
This is important for solar mounting systems because wind loading can generate horizontal forces and bending moments at foundation level.
Lateral performance is affected by:
- Soil stiffness and strength.
- Ground screw diameter and shaft stiffness.
- Embedment depth.
- Ground surface conditions.
- Loading height and direction.
- Interaction between the foundation and the supported structure.
ASTM D3966/D3966M provides a reference method for static lateral load testing of deep foundation elements.
A lateral load test is different from both axial compression and axial pull-out testing. Results from one loading direction should not be substituted for another.
3. SGS Ground Screw Mechanical Test: Method and Results
PV Mounts has SGS mechanical test information for a ground screw specimen. The test arrangement and recorded deformation are important when interpreting the result.

3.1 Test Setup and Loading Arrangement
According to the available test information, the specimen was placed horizontally on two supports. A loading head applied a vertical force at the midpoint between the supports.
The reported test conditions were:
| Test parameter | Reported information |
|---|---|
| Testing organization | SGS-CSTC Standards Technical Services Co., Ltd., Xiamen |
| Test date | April 28, 2015 |
| Support arrangement | Two supports |
| Distance between supports | 1,000 mm |
| Support diameter | 30 mm |
| Loading head diameter | 30 mm |
| Loading position | Midpoint between the two supports |
| Loading speed | 12 mm/min |
| Loading procedure | Vertical loading until the specified test endpoint |
The specimen was supported at two points spaced 1,000 mm apart, with the force applied vertically at the midpoint.
Engineering interpretation: This arrangement is consistent with a three-point-bending-type loading configuration, provided the specimen was positioned horizontally and loaded transversely as described.
It evaluates the specimen’s response to a concentrated transverse load. It is not the same as applying a downward force along the longitudinal axis of an installed ground screw foundation.
The available test information does not establish all specimen dimensions, such as the exact outside diameter, wall thickness, overall length and detailed helical blade geometry. These dimensions should not be assumed when interpreting or comparing the result.


3.2 Maximum Recorded Force and Displacement
The reported mechanical test result was:
| Parameter | Result |
|---|---|
| Maximum compress force reported by SGS | 1,680 kgf |
| Peak value shown in the test curve | 1,679.934 kgf |
| Approximate force conversion | 16.47 kN |
| Displacement at the reported peak | 18.382 mm |
The reported maximum force of 1,680 kgf is approximately equivalent to 16.47 kN.
The test curve recorded a peak value of 1,679.934 kgf, with a corresponding displacement of 18.382 mm.
These values describe the response of the tested specimen under the specified laboratory loading arrangement. They should be reported together with the test setup rather than presented as a standalone ground screw capacity rating.

3.3 Observed Deformation and Test Interpretation
The reported test observations included:
- Noticeable indentation at the central loading position.
- Bending deformation around the midpoint of the specimen.
- No reported fracture of the welds.
- No reported fracture of the helical blade structure.
The observed deformation is consistent with the central loading arrangement: the specimen experienced a concentrated transverse force between two supports, producing bending behavior around the loading position.
The fact that the welds and helical blade structure did not fracture in the reported observations is useful information about the tested specimen under these specific conditions.
However, it does not prove that every ground screw configuration has the same mechanical performance. The result applies only to the tested specimen and the recorded test arrangement.
3.4 What Does the SGS Test Result Demonstrate?
The SGS test provides component-level mechanical information about how the tested ground screw specimen responded to a transverse mid-span load.
For procurement and technical evaluation, the result provides several useful reference points:
- Maximum recorded force: The specimen reached a reported maximum force of approximately 16.47 kN.
- Displacement: The corresponding displacement was 18.382 mm.
- Deformation behavior: Noticeable indentation and bending deformation occurred at the central loading position.
- Observed structural condition: The welds and helical blade structure did not show reported fracture during the test observations.
These observations can help buyers understand the mechanical behavior of the tested specimen. However, the result must not be interpreted beyond the actual test conditions.
The 16.47 kN result does not represent:
- The allowable axial compression capacity of an installed ground screw.
- The ultimate pull-out resistance of a ground screw foundation.
- The lateral resistance of a ground screw installed in soil.
- A guaranteed load rating for every ground screw size or configuration.
- A universal design value that can be applied directly to an EPC project.
An installed ground screw interacts with the surrounding soil. Its foundation performance depends on soil strength, embedment depth, geometry, installation quality and the applicable design criteria.
For engineering approval, the laboratory test information should be reviewed together with product drawings, specimen dimensions, the original test setup and project-specific geotechnical information.
4. Ground Screw Pull Strength and Soil Conditions
The pull-out resistance of a ground screw is strongly influenced by the surrounding soil.
Soil investigation data help engineers understand ground conditions and select an appropriate foundation configuration.
One commonly used soil investigation parameter is the Standard Penetration Test (SPT) N-value.
4.1 What Does the SPT N-Value Mean?
The SPT N-value represents the number of hammer blows required to drive a split-barrel sampler through the specified penetration interval during a Standard Penetration Test.
It is commonly used in geotechnical investigations to help characterize subsurface conditions.
The N-value can provide useful information for preliminary soil assessment, but it is not a direct measurement of ground screw pull-out resistance.
Interpretation depends on factors such as:
- Soil classification.
- Hammer energy and equipment.
- Borehole and drilling conditions.
- Groundwater conditions.
- Overburden pressure.
- Whether the reported value is a measured N-value or a corrected value such as N60.
ASTM D1586/D1586M describes the Standard Penetration Test procedure.
For engineering design, the geotechnical report should clearly identify the test method and any corrections applied to the reported N-values.
4.2 Ground Screw Pull Strength Reference Values
PV Mounts has a technical reference table showing pull strength values under different soil and N-value conditions.
The reference values supplied are:
| N-value | Cohesive soil (kN) | Sand soil (kN) |
|---|---|---|
| 3 | 9.6 | 12.5 |
| 5 | 17.3 | 18.3 |
| 10 | 36.5 | 32.7 |
| 15 | 55.7 | 47.1 |
| 25 | 94.1 | 75.9 |
Important data limitation: These figures are reproduced from the available PV Mounts technical reference data. The underlying test or calculation method, exact ground screw configuration, installation details, soil investigation method and resistance criteria have not been independently established.
The N-values have also not been independently confirmed as measured SPT N-values, corrected N60 values or another soil parameter.
Therefore, these figures should be treated as indicative reference data for preliminary comparison only. They are not presented as SGS-certified pull-out test results, guaranteed field performance or universal allowable foundation capacities.
Before using the values for engineering design, the responsible engineering team should confirm:
- The exact ground screw dimensions and configuration.
- The soil classification and geotechnical investigation method.
- The meaning and correction status of the N-values.
- The installation depth and test conditions.
- Whether the listed resistance represents ultimate, allowable or another defined resistance.
- The applicable safety factors and design criteria.
The table should not replace project-specific geotechnical investigation or field load testing.
4.3 Why Soil Type Changes Ground Screw Pull-Out Resistance
Ground screw pull-out resistance is affected by soil strength, stiffness, density, moisture condition and interaction with the helical plates or other bearing components.
Cohesive soils
In cohesive soils, pull-out behavior can be influenced by undrained shear strength, soil consistency, embedment depth and helical plate geometry.
Soft clay and stiff clay may produce substantially different load-displacement responses. Soil disturbance during installation can also affect the resistance around the foundation element.
Sandy soils
In sandy soils, resistance is influenced by relative density, effective stress, particle characteristics, groundwater conditions and the geometry and depth of the installed ground screw.
Loose sand and dense sand should not be assumed to have equivalent pull-out performance.
For both soil groups, an SPT N-value is only one part of the geotechnical assessment. It should not be used alone to assign a ground screw capacity.
5. Ground Screw Dimensions and Their Influence on Foundation Performance
Ground screw geometry is an important part of foundation selection.
PV mounting projects may use different shaft diameters, wall thicknesses, lengths, flange configurations and helical plate arrangements depending on the structural design and site conditions.
Typical PV Mounts ground screw product configurations include:
| Parameter | Available reference specification |
|---|---|
| Steel material | Q235 |
| Outside diameter | 76 mm |
| Wall thickness | 3.0 mm / 3.5 mm |
| Length range | 1,200–3,000 mm |
| Flange diameter | 200–220 mm |
| Surface treatment | Hot-dip galvanizing |
| Galvanizing thickness | 85 μm for the specified product |
| Galvanizing reference | ISO 1461 for the specified product |
These are examples of available product configurations, not a universal design specification for every project. The applicable galvanizing thickness and product dimensions should be confirmed against the selected product drawing and purchase specification.
5.1 Shaft Diameter and Wall Thickness
The shaft dimensions influence the steel member’s structural stiffness and resistance to deformation. They should be checked against the design forces and relevant structural limit states.
A larger outside diameter or thicker wall does not automatically establish a specific foundation capacity. The complete ground screw configuration and loading conditions must be considered.
5.2 Ground Screw Length and Embedment Depth
The required length depends on the project soil profile, installation depth, loading conditions and foundation design requirements.
A longer ground screw does not automatically guarantee a specific increase in capacity. Effective embedment and the soil layers surrounding the installed screw must be considered.
5.3 Helical Plate Configuration
The number, diameter, spacing and geometry of helical plates affect how the foundation interacts with the surrounding soil.
The appropriate configuration depends on the soil profile and design requirements. The helical plate dimensions should be confirmed against the product drawing rather than inferred from the shaft dimensions alone.
5.4 Hot-Dip Galvanizing and Corrosion Protection
Corrosion protection is important for steel ground screws exposed to outdoor environments and soil conditions.
For the specified PV Mounts product, the hot-dip galvanizing thickness is 85 μm, with ISO 1461 used as the applicable reference. The actual coating requirement should be confirmed for the specific product and project specification.
Soil corrosivity, moisture, chemical conditions and project design life should also be considered when defining corrosion protection requirements.
6. Ground Screw Installation and Its Effect on Load Performance
Ground screw performance is influenced not only by product geometry but also by installation quality.
Depending on project conditions, installation equipment may include portable manual pile drivers or larger hydraulic installation equipment mounted on excavators or other machinery.
Ground screw installation may be considered for different project environments, including:
- Ground-mounted photovoltaic plants.
- Solar carport foundations.
- Off-grid solar installations.
- Selected remote or uneven project sites.
However, suitability must be evaluated for the actual ground conditions and equipment access.
Important installation factors include:
Installation position: The ground screw should be installed at the specified location and orientation.
Verticality or inclination: The installed angle should comply with the project design.
Installation depth: The required embedment depth must be achieved and recorded.
Installation torque or driving records: Where specified by the engineering method, installation records should be collected and reviewed.
Ground conditions: Unexpected obstructions, loose layers, rock or changes in soil conditions should be reported.
Foundation head level: The final flange or connection elevation should match the structural installation requirements.
Installation torque, where used, should not be treated as a universal direct conversion to axial capacity. Any torque-to-capacity correlation needs to be established for the relevant ground screw geometry, equipment and site conditions.
For projects with uncertain soil conditions, trial installations and field load tests may be required before mass installation.
7. Engineering Standards and Reference Test Methods
When reviewing ground screw foundation performance, engineers should distinguish between component mechanical tests, geotechnical investigations and installed foundation load tests.
The following ASTM standards provide reference methods for deep foundation testing and soil investigation:
| Standard | Test or investigation | Engineering purpose |
|---|---|---|
| ASTM D1143/D1143M | Static axial compressive load testing | Evaluates axial compression load and displacement |
| ASTM D3689/D3689M | Static axial tensile load testing | Evaluates axial tension or pull-out response |
| ASTM D3966/D3966M | Static lateral load testing | Evaluates lateral load and displacement |
| ASTM D1586/D1586M | Standard Penetration Test (SPT) | Measures sampler penetration resistance for soil investigation |
These standards provide reference procedures for the corresponding test types. Listing them here does not mean that the PV Mounts specimen test described in Section 3 was conducted in accordance with these standards.
The applicable test procedure and acceptance criteria should be selected by the project engineer according to the foundation system, project specification and local requirements.
8. What EPC Contractors Should Check Before Approving Ground Screws
For EPC contractors, installers and engineering teams, a ground screw supplier’s product catalogue is only one part of the technical evaluation.
Before approving a ground screw foundation for a project, the following information should be reviewed.
8.1 Product Information
- Steel grade and material specification.
- Shaft outside diameter and wall thickness.
- Overall length and effective embedment depth.
- Helical plate dimensions and configuration.
- Flange or connection head dimensions.
- Galvanizing specification and coating thickness.
8.2 Mechanical Test Information
When reviewing test documentation, confirm:
- Test type and objective.
- Sample dimensions and configuration.
- Test arrangement and loading direction.
- Test equipment and calibration information.
- Support conditions and loading speed, where applicable.
- Maximum load and corresponding displacement.
- Deformation or failure mode.
- Whether the tested specimen matches the supplied product.
A maximum force value without its test arrangement and specimen information is insufficient for a complete engineering assessment.
8.3 Geotechnical Information
Provide the engineering team or supplier with available site information, including:
- Geotechnical investigation report.
- Soil classification and soil profile.
- SPT N-values and any applicable corrections.
- Groundwater level.
- Relevant soil strength and stiffness parameters.
- Information about rock, obstructions or variable ground conditions.
8.4 Foundation Design Requirements
The project engineering team should establish:
- Required compression resistance.
- Required pull-out resistance.
- Required lateral resistance.
- Design load combinations.
- Required embedment depth.
- Foundation spacing and layout.
- Applicable design standards and safety factors.
8.5 Installation Records and Field Verification
Depending on project requirements and ground conditions, field testing may be necessary to verify the proposed foundation solution.
The test method, loading procedure, acceptance criteria and test locations should be established by the responsible engineering team.
Installation records should include equipment, installation position, achieved depth, specified torque or driving records, and any installation difficulties or deviations.
9. PV Mounts Solar Ground Screw Solutions
PV Mounts supplies ground screw products for solar mounting applications, including ground-mounted PV projects and solar carport foundations.
Available configurations include:
- Flange-head ground screws.
- Universal ground screw piles.
- Adjustable ground screws.
- Ground screws with different helical plate configurations.
- U-type ground screw solutions.
Typical product configurations include Q235 steel, 76 mm outside diameter, 3.0 mm or 3.5 mm wall thickness, and lengths from 1,200 mm to 3,000 mm. Specific products can be supplied with hot-dip galvanizing requirements, including the 85 μm specification for applicable configurations.
Final product selection should be based on project drawings, geotechnical conditions, structural loading and installation requirements.
For EPC contractors, distributors and solar mounting system importers, PV Mounts can provide product information and configuration support for project evaluation.
Explore our Solar Ground Screw Product Range.
Request a Ground Screw Quotation
To help us review your project requirements, please provide:
- Required ground screw dimensions.
- Project quantity.
- Mounting structure or flange drawings.
- Project location.
- Available soil investigation information.
- Required surface treatment and inspection documentation.
If your project already has an approved ground screw drawing, you can send it for a manufacturing and specification review.
Contact PV Mounts with your ground screw drawings and project requirements to discuss product configurations and request a quotation.
10. Frequently Asked Questions About Solar Ground Screw Load Testing
Solar ground screw load testing evaluates how a ground screw or installed foundation responds to applied loads. The main loading directions include axial compression, axial tension or pull-out, and lateral loading. Each test evaluates a different aspect of foundation performance.
Compression testing applies a downward load along the foundation axis, while pull-out testing applies an upward axial load. Compression and pull-out resistance are different engineering properties and should be evaluated separately.
The reported maximum compress force was 1,680 kgf, approximately 16.47 kN. The corresponding displacement was 18.382 mm. The specimen was supported at two points 1,000 mm apart and loaded vertically at the midpoint.
No. The test used a two-support, mid-span loading arrangement, which is consistent with a three-point-bending-type test. It provides component-level mechanical information about the tested specimen, not the allowable axial compression capacity of a ground screw installed in soil.
No. A compression-related mechanical test does not establish axial tensile or pull-out resistance. Pull-out performance requires an appropriate tensile load test or a justified engineering assessment based on project-specific soil and foundation information.
The SPT N-value represents the penetration resistance measured during a Standard Penetration Test. It helps characterize subsurface soil conditions, but it is not a direct measurement of ground screw pull-out capacity. Engineers must consider soil classification, test conditions and any required corrections.
Not necessarily. Soil type, soil structure, groundwater, effective stress, helical plate geometry and installation conditions also influence pull-out behavior. N-values should be interpreted together with the complete geotechnical investigation.
PV ground screw configurations may include a 76 mm outside diameter, 3.0 mm or 3.5 mm wall thickness, and lengths from 1,200 mm to 3,000 mm. The appropriate dimensions depend on project loads, soil conditions and foundation design.
Suitability depends on the actual ground profile, rock content, obstructions, equipment access and installation method. A site investigation and trial installation may be necessary before selecting a ground screw foundation for such conditions.
No. Installation torque can be a useful construction control parameter when a project-specific correlation has been established. It should not be converted directly into a universal load capacity without supporting engineering evidence.
ASTM D1143/D1143M addresses static axial compression testing, ASTM D3689/D3689M addresses static axial tension testing, and ASTM D3966/D3966M addresses lateral load testing of deep foundation elements. ASTM D1586/D1586M covers the Standard Penetration Test used in soil investigation.
Important information includes project location, soil investigation report, structural loads, ground screw dimensions, required embedment depth, connection details, corrosion protection requirements and installation equipment. These details help engineers evaluate the appropriate foundation configuration.
Conclusion
Solar ground screw performance cannot be evaluated by product dimensions or a single mechanical test result alone.
A reliable engineering assessment should distinguish between axial compression, axial pull-out and lateral resistance, while considering soil investigation data, ground screw geometry, installation conditions and project-specific design requirements.
The SGS mechanical test discussed in this article recorded a maximum force of approximately 16.47 kN and a displacement of 18.382 mm under a two-support, mid-span loading arrangement. The observed indentation and bending deformation provide useful information about the tested specimen. However, this result must not be treated as the axial compression capacity or pull-out resistance of an installed ground screw foundation.
For EPC contractors and solar mounting system designers, the most useful technical documentation combines clear product specifications, traceable test methods, load-displacement records, geotechnical information and installation records.
Supports PV supplies ground screw configurations for solar mounting applications and supports project-based product selection. Contact our team with your project drawings, soil information and technical requirements to discuss a suitable ground screw configuration.